Maxon 4 Ff 5000 Cp 1 Natural Gas Safety Shut Off Valve 6 Seconds

maxon 4 Ff 5000 Cp 1 Natural Gas Safety Shut Off Valve 6 Seconds
maxon 4 Ff 5000 Cp 1 Natural Gas Safety Shut Off Valve 6 Seconds

Maxon 4 Ff 5000 Cp 1 Natural Gas Safety Shut Off Valve 6 Seconds High pressure regulators up to pn40 (ansi 300) medium pressure regulators up to pn16 (ansi 150) pilot heater. safety relief valves. safety shut off valves. series 200 small pressure regulators (pressure reducer) series 600 control equipment for safety shut off valves. series 600 pilot regulators for pilot operated gas pressure regulators. Honeywell maxon electromechanical safety valves shut off gas lines in less than one second. all shut off valves come equipped with maxon's long lasting metal to metal seating. a variety of optional body materials and body connections provide reliable operation even for highly corrosive fuels and for oxygen. application flexibility is provided.

maxon Corporation 4 ff 5000 cp 1 gas valve Ims Suppl
maxon Corporation 4 ff 5000 cp 1 gas valve Ims Suppl

Maxon Corporation 4 Ff 5000 Cp 1 Gas Valve Ims Suppl All shut off valves come equipped with maxon’s long lasting metal to metal seating. a variety of optional body materials and body connections provide reliable operation even for highly corrosive fuels and for oxygen. application flexibility is provided with 3 4″ through 6″ diameter line sizes, cv flow factors up to 1230, and line. Maxon safety shut off valves documentation. maxon gas electro mechanical valves technical catalog. pdf, 4.04 mb. maxon 5000 series technical catalog. pdf, 4.03 mb. maxon oil electro mechanical valve hazardous location technical data sheet. pdf, 2.42 mb. maxon oil electro mechanical valve product overview brochure. pdf, 1.72 mb. Installing valve into line. for new installations, a gas filter or strainer shall be installed in the fuel gas piping to protect the downstream safety shut off valves. per nfpa 86 4 2.4.3 (1999) nfpa 86c 4 2.4.3 (1999) nfpa 86d 4 2.4 3 (1999) if normal inlet pressure to the fuel pressure regula tor immediately upstream from the valve exceeds. Description. maxon electro mechanical valves are electrically actuated fuel shut off valves. the valves are designed for a fast acting return to the at rest position upon removal of a control voltage signal. motorized automatic and manual actuators are available depending on application needs.

maxon 4 Ff 5000 Cp 1 Natural Gas Safety Shut Off Valve 6 Seconds
maxon 4 Ff 5000 Cp 1 Natural Gas Safety Shut Off Valve 6 Seconds

Maxon 4 Ff 5000 Cp 1 Natural Gas Safety Shut Off Valve 6 Seconds Installing valve into line. for new installations, a gas filter or strainer shall be installed in the fuel gas piping to protect the downstream safety shut off valves. per nfpa 86 4 2.4.3 (1999) nfpa 86c 4 2.4.3 (1999) nfpa 86d 4 2.4 3 (1999) if normal inlet pressure to the fuel pressure regula tor immediately upstream from the valve exceeds. Description. maxon electro mechanical valves are electrically actuated fuel shut off valves. the valves are designed for a fast acting return to the at rest position upon removal of a control voltage signal. motorized automatic and manual actuators are available depending on application needs. Open the upstream manual gas valve (a) to pressurize the first ssov. immerse the 1 4 in (6mm) tube vertically 1 2 in. (13mm) in a jar of water. slowly open the manual test petcock (f). when the rate of bubbles coming through the water stabilizes, count the number of bubble appearing during a ten second period. Safety device in gas pressure regulating stations. applicable for use with natural gas according to dvgw g 260; other gases available upon request. characteristics. maintenance friendly, interior parts accessible without device removal, made up of few parts. integrated pressure equalisation valve. low pressure loss thanks to axial flow.

Comments are closed.